Herunterladen Inhalt Inhalt Diese Seite drucken

Preset Adjustment - Service 06 Hex; Data-Check - Service 08 Hex - TR-Electronic 582-Serie Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für 582-Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameterization

5.2.5 Preset Adjustment - Service 06 Hex

Via the preset adjustment, the measuring system can be adjusted over the
INTERBUS-S ring to a certain value.
Only writing possible.
Value range: 0 up to the programmed measuring length in steps (value from service 02
Hex).

5.2.6 Data-Check - Service 08 Hex

After the measuring system is programmed, the data check service must be executed.
This call checks the validity of the programmed data and accepts it. Without this call,
the measuring system continues to run with the old parameters until you switch the
power off and on again.
Only reading possible.
As response on 2
The bits 2
The bits 2
Error Status
0
2
Error reading data
1
2
Error writing data
2
2
Only reading allowed
3
2
Only writing allowed
4
2
Always 0
5
2
Always 0
6
2
Always 0
7
2
Unknown command
8
2
Preset 1 outside of the valid measuring range
9
2
Preset 2 outside of the valid measuring range
10
2
Always 0
11
2
Always 0
12
2
Always 0
13
2
Revolutions numerator = 0
14
2
Measuring length exceeded. Measuring length/360° > resolution (see name plate)
15
2
Always 0
If an error occurs at execution of a service (error bit set in measuring system's service
feedback message), you can determine the error exactly by carrying out the data
check service.
 TR-Electronic GmbH 2022, All Rights Reserved
Page 40 of 43
0
15
to 2
of the IN data the master receives the error status
16
23
to 2
of the IN data are "0".
24
31
to 2
of the IN data report back the requested service.