● Do not cover open light guide holders or light guide outlets at any time! Risk of fi re!
● Avoid at all cost covering open light guide holders or light guide outlets by hands or other parts of the body. Risk of burns!
● When illuminating heat-sensitive or infl ammable light-absorbing objects (e.g. in microscopy), make sure there is a distance
between the relevant material and the employed light guides, and adjust the intensity of the light source so as to prevent
damage to the object.
● All light guide outlets that are not in use during operation must be kept at a safe distance – i.e. at least 10 cm – from
heat-sensitive or infl ammable light-absorbing materials while the light source is switched on.
● Biological tissue may be exposed to unnecessarily high stress and may be subject to damage during excessive illumination
with visible light, hence the intensity of the light source and the duration of illumination of such tissues should be limited to
the absolutely necessary levels and periods.
The cold light source may only be operated at the voltage indicated on the nameplate (9).
Ensure a safe protective conductor connection.
The cold light source was developed for indoor use in dry rooms.
The cold light source must not be used in potentially explosive environments.
Safe disconnection from power supply can only be ensured by pulling the mains plug.
All ventilation openings (7, 8) must be uncovered at all times to ensure suffi cient cooling of the device. In case of insuffi cient cool-
ing an integrated sensor will continuously control light intensity down until shutdown to protect the illuminant from overheating and
damage. In this case, the LCD (3) will issue an error message (see Chapter 3.5. for LCD messages).)
The device may only be opened or disassembled by authorised service personnel. Technical changes on the device are prohib-
ited. Repair may only be effected by manufacturer or authorised service personnel.
These Operating Instructions must be swiftly available and accessible to any device operator.
Manufacturer does not assume liability for any damage that results from failure to observe these Operating Instructions.
26
Stand Oktober 2015