4 M E N U - S E T T I N G S
Push the buttons to navigate to the specified screens (listed on the next pages).
Password protected zone! All protected for 0002, only 'change time system'
and 'product' is a protected zone (User level 4)! The menu 'change time system'
is user level 2 zone (password for user 0001).
For each box it is possible to determine for which programs the shampoo
pump will be used and which amount of product need to be dosed. Also the
other possible pumps (wax/shine rinse/pre soak/insect cleaner/motor cleaner/
degreasing/... - depending which one is desired) can be adjusted here. The
black vertical line indicates the manually de aeration or stopping of the
shampoo pump with the blue and red button on top. The percentage of the
product can also be determined here. The manual de aerating or stopping of
the machine happens by the red/blue buttons on the right side. This for the
shampoo, wax pump and third additional dosage pump.
Be careful: if you want to vent the product in the pumps, you have to
first define the boxes in default! This can happen by pushing the
manual button if the values are being reset. Now it is possible to vent
the pumps.
Manual operation of lighting is indicated on this page.
The hours of lighting can be adjusted separately. If both times are set on
0:00, the lighting will only light (on the box) when a coin is inserted in the coin
acceptor of the box. When the off- time is set on for example 24.00h, the lights
will go off after this set time. When a client want to use the car wash after this
hour, the box where he inserts a coin in the coin acceptor will light up. You can
also add an extra waiting period after closing time.Here you also can see the
setting (possible to change), luminance and night message of the lighting (not
possible to change). The night message is a visualisation of the luminance
regulation.
Attention: with delay, after waiting time!