16.2 Operation
16.2.1 Operating console
16.2.2 Automatic operation
HOLZMANN MASCHINEN GmbH
www.holzmann-maschinen.at
Main switch (1)
Switch power supply on and off
Control lamp (2)
Lights up when the power supply is switched on
Selector switch for cutting speed (3)
Select the speed of the saw band:
NEUTRAL (switch position 0)
SLOW (switch position 1)
FAST (switch position 2)
START button (4)
Switch on band saw in automatic mode
Selector switch for operating mode (5)
Selection of manual or automatic operation of the
saw arm.
AUTOMATIC OPERATION (switch
position left)
MANUAL OPERATION (switch position
right)
EMERGENCY STOP switch (6)
Switch off the machine in an emergency.
Only after the malfunction has been rectified and
there are no risks left:
Release the EMERGENCY switch by turning it
clockwise.
The machine can now be started again.
Lift the saw arm to the maximum height to
release the spring.
Close the feed control (8) to hold the arm in
position.
Lift the fixing knob (9).
Now the lever (10) can be moved upwards to
the "automatic" position.
To fix the lever (10), return the fixing knob
(9) to its original position.
Turn the selector switch of the operating
mode (11) counterclockwise to automatic
operation (see 16.2.1).
Select the cutting speed (12).
Turn the main switch (13) to the ON position.
Control lamp (14) must light up.
OPERATION
35
BS370TOP