6.2.

Diaphragm change

The diaphragm has to be controlled for wear after max. 100.000 (≥MA80 50.000) switching
operations. Depending on working load, the control period has to be reduced according to valid
regulations and rules.
Particles in the working media can be abrasive – reduce control period accordingly.
Only use diaphragms which are suitable for your application.
Don't use higher control pressure than necessary. This helps to save the diaphragm.
Note!
Media leakage by wrong assembly!
Ensure correct assembly before startup!
Danger!
Danger of injury through high pressure!
Pressure acting on lines and valves may cause severe injuries!
Before disconnecting any lines and valves, the pressure must be switched off and the lines must be vented.
Protect the facility from inadvertent operation!
Danger through media leakage (steam, hot media, acid, lye)
© 1996 - 2020 SED Flow Control GmbH