6 Installation
6.1 Housing opening
Loosen the 2 screws on the side, turn the cover and
the upper half of the body about the opening hinge
axis.
Fig. 1
After installation and wiring, close the
product.
MNVCHOV32_2104_EN
6.2 How to install the camera
Power supply can be provided by the board
supplied with the product. Make sure the
voltage values are appropriate.
Open the housing as described in the relative chapter
(6.1 Housing opening, page 7).
Partially loosening the fastening screws (01).
Remove the internal slide (02) by sliding it until the
holes coincide with the slide fastening screws.
Fasten the camera with the 1/4" screw (03). To
position the camera and lens correctly, if necessary,
use the supplied spacers. (04).
03
01
03
Fig. 2
Reposition the internal slide and tighten the screws
that had been loosened previously.
Remove the conductors protective sheathing and
connect them to terminal (J5, 6.3 Board description,
page 8).
The camera's power supply cable conductors must be
tied up with a cable tie next to the terminal. Keep the
signalling and power supply cables separated from
each other.
02
7