Herunterladen Inhalt Inhalt Diese Seite drucken

Data Plate - Homa H 842 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.3.1. Data plate

1 Ph
3 Ph
3.3.2. Motor
The motor consists of a stator and the motor shaft with the rotor set. The lead for supplying power is designed for
the maximum mechanical power in accordance with the characteristic curve or data plate of the pump. The cable
entries and the lead are sealed watertight against the conveyed medium. The shaft bearings are robust,
maintenance-free and permanently greased roller bearings.
General motor data
Mode of operation
Permissible medium temperature
Insulation class
IP Code
Cable length
Voltage version W
Voltage version D
3.3.3. Monitoring systems
Direction of rotation control
No check is necessary for 1ph motors, since these always run in the correct direction of rotation.
3ph motors run in the correct direction of rotation when connected to a clockwise rotating field (U, V, W -> L1, L2,
L3). HOMA switchgear checks the grid for a clockwise rotating field. If there is no clockwise rotating field, the red
LED is lit. Two phases are to be exchanged at the input to the switchgear. With smaller pumps, the check can be
made by observing the starting jerk. For this purpose, place the pump perpendicular to the floor, slightly on edge,
and switch on briefly. Seen from above, the pump jerks slightly anticlockwise if the direction of rotation is correct.
The direction of rotation of the pump is correct if the pump moves anticlockwise because, seen from above, the
motor starts in the clockwise direction.
30
No.
1 Ph
1
Type description
2
Serial number
3
Impeller diameter
4
Temperature of medium
5
Immersion depth
6
Weight
7
Hmax (delivery head max)
8
Hmin (delivery head min)
9
Qmax (delivery volume max)
10
Standard
11
Construction
regulations-test lab
12a
Year type test
12b
Declaration of performance
13
Build year
14
Motor type
15
IE Marking
16
Frequency
17
Voltage
18
Nominal current
19
Motor RPM
20
Power P1
21
Cos phi
22
Insulation class
23
Power P2
24
Start condenser
25
Operating condenser
26
Protection class
27
Operating class
28
Text field sales
S1
35°C
B (130°C)
IP68
1 m
230V / 50Hz / 1Ph
400V / 400V / 3Ph
3 Ph
Type description
Serial number
Impeller diameter
Temperature of medium
Immersion depth
Weight
Hmax (delivery head max)
Hmin (delivery head min)
Qmax (delivery volume max)
Standard
product
Construction
regulations-test lab
Year type test
Declaration of performance
Build year
Motor type
IE-Marking
Frequency
Voltage – 3-phase
Nominal current 3-phase
Motor RPM
Voltage – Star connection
Nominal
current
connection
Insulation class
Power P1
Cos phi
Protection class
Power P2
Operating class
Text field sales
product
Star

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

H 846H 847H 863H 862H 844

Inhaltsverzeichnis