6.9.1
Circuit Diagram for 24V BG 66 dPro Motors
example:
connection of a switch/sensor
from logic /PLC
U+
power supply
GND-
soft start circuit
(if not otherwise
provided by
power supply)
2,2 Ohm
> 50 W
2x MCB*
U+
B-type 16 A
from
power supply
GND-
* MCB: Miniature circuit breaker, use DC-suitable UL listed inverse-time circuit breakers.
Select the rated current of the circuit breaker according to the used wire diameters.
Earth the system for functional reasons (EMC).
X
Page/Seite 44 / 51
MCB*
A-type 1 A
example:
signal lamp, actor
...to next motors
2,2 Ohm
8 A
≥ 50 W
time
ballast
lag
circut on
fuse
request
...to next motors
6.9.1
Schaltplan für 24V BG 66 dPro Motoren
M16, 12+3 in Power- and
Logic connector
1
IN 0
2
IN 1
3
IN 2
4
IN 3
5
OUT3
6
IN4
7
AI +
8
AI -
9
U Logic
10
OUT 1
11
OUT 2
12
N. C.
-
~
U-POWER
A
GND Logic + POWER
B
BALLAST
C
BG 66 dPro
connect housing to machine earth
for EMC shielding
System aus funktionalen Gründen (EMV) erden.
X
BG 66
dPro
Alternative: Industrial Ethernet
M12 CAN
from control unit (CO version)
Male con.
CAN H
4
CAN L
5
M12 CAN
to next device (CO version)
Female con.
CAN H
4
CAN L
5
M
Version 13-01-2022