Herunterladen Inhalt Inhalt Diese Seite drucken

Operation In Safety-Related Applications; Scope Of Delivery; Transport, Packaging And Storage - WIKA TIF50 Betriebsanleitung

Feld-temperaturtransmitter mit hart-anzeigemodul
Vorschau ausblenden Andere Handbücher für TIF50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. Design and function / 5. Transport, packaging and storage
4.2 Dimensions in mm (aluminium and stainless steel)
The field instrument consists of a model T32 temperature transmitter with integrated
indication and operating module, models DIH5x-B or DIH5x-Z.

4.3 Operation in safety-related applications

The field temperature transmitters models TIF50, TIF52 are suitable for use in
SIL
safety-related applications.
IEC 61508 / IEC 61511

4.4 Scope of delivery

Cross-check the scope of delivery with the delivery note.

5. Transport, packaging and storage

5.1 Transport
Check the instrument for any damage that may have been caused by transport.
Obvious damage must be reported immediately.
5.2 Packaging
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during transport (e.g. change in
installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -40 ... +85 °C
Humidity: 35 ... 85 % r. h. (non-condensing)
WIKA operating instructions models TIF50, TIF52