CR2011
OUTPUT MODULE
Technical data
Housing
Dimensions
Device connection
Operating temperature
Storage temperature
Protection rating,protection class
Operating voltage (U
)
B
Current consumption
Indicators
Interface
Baud rate
Communication profile
Device profile
CAN
Node ID (default)
Binary outputs
Switching voltage
Switching current
Total current
PWM outputs
Output frequency
PWM pulse/break ratio
Resolution
Current outputs
Output current
Resolution
26
PAGE
All manuals and user guides at all-guides.com
8-channel splitter box made of special PUR with integrated elec-
2 x 1.5mm² (operating voltage) / 3 x 0.5mm² (CAN interface)
≤ 100 mA, without external load
CAN interface - ISO 11898 version 2.0
I/O module to CiA DS401, CiA DS301 V3.0
8 semiconductor outputs, short-circuit/overload protected
max. 2 A (with current monitoring)
max. 4 A (without current monitoring)
Current monitoring of two channels each selectable by means
of wire connection. The following channels are
2 outputs each can be configured as PWM channel
With the configuration as PWM output the status LED is
- for PWM values > 100 mA (with current monitoring)
2 outputs each can be configured as current channel
setting resolution 1 mA, useful resolution typ. 2.5 mA
tronics, fully potted
152 x 60 x 25 mm (L x W x H)
PUR/PVC cable 2 m,
M12 connector for outputs
-25 °C ... +85 °C
-40 °C ... +90 °C
IP 67 III
10 ... 30 V DC
LED green: Run LED
LED red: diagnostic LED
LED yellow: output status
10 Kbits/s - 1 Mbits/s
CANopen
Full-CAN
hex 20 (= 32)
10 ... 30 V DC
combined: 1+2, 3+4, 5+6, 7+8
max. 16 A
20 ... 150 Hz
1 ... 1000 ‰
1 ‰
permanently lit
- for PWM values ≠ 0
100 mA ... 2.5 A