Hand-Held Pressure Indicator
CPH6200-Ex (Atex-Version)

8. Calibration services

DKD-certificates - other certificates:
If the instrument requires calibration, we recommend returning it, along
with its associated sensors, to the manufacturer. Only the manufac-
turer is able to verify the instrument's basic settings and configuration,
and if necessary correct them.
9. Specifications
Input
Pressure range in bar
Overpressure safety in bar 1
Burst pressure in bar
Resolution in mbar
Pressure range in bar
Overpressure safety in bar 35
Burst pressure in bar
Resolution in bar
Type of pressure
Accuracy of the
measuring chain
Calibration*
Display
Range of display
Units
CPH6200-Ex Digital Instrument specific details:
Functions via key press Min-, Max-memory, Hold, Tare, Offset-correction, Logger (Start/Stop)
Functions via Menu
Data logger
Interface
Power supply
Power consumption
Working temperature
Air humidity
Storage temperature
Housing
Weight
EMV- / CE-conformity
1)
For the intrinsically safe version, the use of the interface is not permitted within an explosive
atmosphere.
*)
Calibrated in vertical mounting position with lower pressure connection.
{}
Items in curved brackets are optional extras at an additional price.
WIKA Operating Instructions Hand-Held Pessure Indicator
1 connector socket
0.1
0.16 0.25 0.4
1.5
2
2
10
16
80
42
96
gauge {absolute 0.25 up to 16 bar & vacuum on request}
0.2 % FS +/- 1 digit at reference temperature of 20 °C
factory calibration certificate (optional: DKD calibration certificate)
large LCD display for display of 2 four-digit values and additional
information
max. -19999 up to 99999, depending on sensors used
can be selected from the following: mbar, bar, Pa, kPa, MPa, mmHg,
psi (dependent on range)
Min-, Max-alarm (visual), Sea-level (barom. air pressure),
Power-Off-Function, measuring rate: 4/sec ("slow"); > 100/sec
("fast"); > 100/sec unfiltered ("peak-detect") [via "peak-detect" and
min-/max-memory: pressure peaks of 10 msec can be detected]
- discrete value-logger: up to 99 data points (incl. time-stamp) via key press
- cyclic-logger: automatic logging of up to 10000 values incl. time.
Cycle-time: selectable between 1 ... 3600 seconds
(serial)
RS-232 interface via interface converter {USB adapter on request}.
1)
9V-zinc-carbon battery
Cycle-time slow: < 1.5 mA, fast: < 3.0 mA, Low-Power-Logger-Fct.: < 0.1 mA
0 ... 50 °C
0 ... 95 % relative humidity without moisture condensation
-20 ... +70 °C
Impact-resistant ABS, membrane keyboard, transparent panels, cover
Approx. 160 g
The CPH6200-Ex device corresponds to the essential protection
requirements established in the regulations of the council for the
approximation of legislation of the member countries regarding
electromagnetic compatibility (89/336/EWG).
0.6
1.0
1.6
2
2
4
5
10
2.4
2.4
4.8
6
12
0.1
25
40
60
100
160
50
80
120
200
320
250
400
550
800
1000 1200 1700 2400 3000
0.01
GB
2.5
4.0
6.0
10
17
35
12
20.5
42
1
250
400
600
1000
500
800
1200 1500
0.1
1
21