Herunterladen Diese Seite drucken

Connecting The Drive Motors; Connecting The Battery; Connecting The Safety Socket - Truma Mover XT Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Mover XT:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Installation behind axle
E
1
3
A
B
+
-
-
+
+
-
C
Figure 32
Once the cables have been routed out of the control unit, they
must be strain-relieved.

Connecting the drive motors

The data and motor cables must be routed together in such a
way that they cannot be torn off or damaged.
The cables may be shortened. Please pay attention to
different ring eyelet sizes.
Release the cover of the control unit by applying lateral press-
ure to the latching lugs, and clamp the cables as shown in
the connecting diagram (red = positive, black = negative).
Please ensure that the connections are made properly. (Torque
M5 = 3.5 Nm / M6 = 6.0 Nm)

Connecting the battery

Liquid electrolyte batteries must be installed in a separate
box with ventilation leading to the outside. The fuse in the
positive lead must be connected outside the box. A separate
box is not required for gel or AGM batteries. Pay attention to
the battery manufacturer's installation instructions.
The outgoing lines from the terminals must be routed with a
gap between them until after the fuse in the positive lead.
-
+
Figure 33
Route the battery connector cables (only use the original
Truma cables supplied) to the control unit and attach them
securely using the clips and screws provided.
D
5
7
9
M6 = 6 Nm
M5 = 3.5 Nm
-
+
Figure 34
The battery connector cables must not be extended.
They must be routed separately from the motor cables,
and must not run over the control unit.
Route battery connector cables so that they do not chafe
(particularly at leadthroughs through metal panels). Use
suitable protective leadthrough bushing to prevent damage
to cables. Connect battery connector cables to the existing
battery terminals (red = positive, black = negative).
Incorrect polarity will destroy the electronics / control
unit
The connection to the control unit (as per the connecting dia-
gram) must be made in the order: nut, battery connection ring
eyelet, nut (torque M6 = 6.0 Nm).
Connect fuse in the positive lead (150 A) near the positive ter-
minal of the battery.

Connecting the safety socket

Route the 2-wire cable provided (9 m or 10 m) with the flat
connectors through the socket holder (g) and the rubber
sleeve (h).
If necessary, open cover and push socket connection out of
socket housing (i).
Connect 2-wire cable with flat connectors to micro switch.
RD / BK
Figure 35
BK
27