Operation
Description
4
Two people are required to replace the
cover on the MPreC test bench . Do not
knock the signal pin when doing this .
CAUTION
It is recomended to fit the hood to the lower
part of the test bench by two people .
6
Connect the compressed air supply via
the existing G1/2" connection .
CAUTION
The pressure of the compressed air fed in
must be min . 4 bar and max . 10 bar .
The national regulations must be observed
for secure attachment of the compressed
air supply using the existing compressed air
connection .
7
Connect the power supply via the power
cable supplied and switch the device on .
Ensure appropriate protection against
the weather as appropriate when using
outdoors .
8
The LED in the centre of the emergency
stop push-button lights up red during
operation of the MPreC test bench .
You can operate this push-button to
shut down the test bench at any time
after switching it on .
9
Establish a connection to your PC or
notebook using the USB port and the
USB cable supplied and launch the
MPreC applications software .
22
WARNING
CAUTION
Image
NOTE
Use only clean compressed air in 2 .2 .4
quality (dust, oil and water free) in accor-
dance with ISO 8573-1: 2001 (E) .