Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use/Function; Initial Installation; Fitting The Wall Bracket; Installation - BWT Woda Pure 120 Einbau- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
Do not exceed the maximum inlet pressure.
Caution! If the inlet pressure is greater than 8 bar,
a pressure reducer must be fitted in front of the filter.
Then set the inlet pressure to 4 bar.
A minimum inlet pressure of 1 bar is required for the
filter to function. In the event of pressure fluctuations
and pressure surges, the sum of pressure surge and
standing pressure must not exceed the nominal pres-
sure of 8 bar. In the process, the positive pressure
surge must not exceed 2 bar and the negative pres-
sure surge must not exceed 50 % of the adjusting
flow pressure (see DIN 1988 Part 2.2.4).
6. Intended use / Function
Filter for the removal of undesirable odours or
flavours (e.g. chlorine), natural colorants (e.g. hu-
mic substances) and for the disinfection of drinking
water.
The water first flows through active carbon.
The large surface and the porosity cause the ad-
sorption of undesirable dissolved organic matter.
Natural colorants and odours are thus removed. At
the same time any existing suspended sediments are
separated.
The water is then membrane filtered.
This is a "dead-end-microfiltration" system.
The pore width is so small that bacteria cannot pass
through. The filter is also fitted with bac-tericide to
ensure the service life of 6 months. Without the bac-
tericide, the bacteria may start to "spread".
Only with Woda-Pure Energy:
The Woda-Pure Energy filter also helps reduce the
build-up of lime in pipes.
Annoying lime residue can thus be avoided to a
large extent.

7. Initial installation

Important:
Do not use brute force when install the filter, as this
will render the filter warranty null and void!
The technical data (section x) and also the operation
and safety instructions (section x) must be followed.
If the product has been stored at under 0° C, the
unpacked product must be exposed to the ambient
temperature of the installation site for at least 24
hours before it is operated.
12
000_EBA Woda-Pure.indd 12
All manuals and user guides at all-guides.com
When fitting accessories (hoses, connection sets,
etc.), note the fitting dimensions, bending radii and
dimensions.
7.1 Fitting the wall bracket (accessories – not
included in the delivery)
Attach the mounting clamp to a suitable
-
spot using
Fitting height should be at least 400 mm.
-

7.2 Installation

Install the water tap at a
-
suitable spot. (accessories –
not included in the delivery)
Fasten the stainless steel gauze
-
hose to the corner valve using
lock nuts. (accessories – not
included in the delivery)
Connect the point of the filter
-
unit to the stainless steel gauze
hose.
Insert the blue hose completely
-
into the filter unit.
Lightly pull on the blue hose,
-
the connection is now tight.

7.3 Start-up

Slowly open the corner
-
valve
Activate the water tap by
-
pressing on the lever until
water comes out.
Check that the installation
-
is sealed tight.
Let water flow for 5 minutes,
-
dispose of this. After 5 minutes of constant
flow, the water can be used.