IV. Fitting tools
• Phillips screwdriver
• Drilling machine for wood, metal and walls
• Metal drill:
(also use with wood)
• Masonry drill bit:
• Milling cutter/hole saw:
• Mechanic's level, metering rule
• Hexagon socket screw key SW 3, SW 4, SW 5
• Metal saw, file
• Tools for additional work are not included in this installation
V. Replacing the door cylinder
If the door cylinder does not need to be replaced, continue to read under chapter VI.
Warning: The VdS recognition only applies in connection with the use of a VdS class A or a
higher class of door cylinder.
With door leaf strengths above 50 mm and/or if the door cylinder has to fit in a locking
system, the standard door cylinder must be replaced.
The same applies if it is set to be fitted without any "option to lock from outside".
1. New door cylinders correspond to DIN EN 1303/DIN 18252 and obtain spacers and longer
screws if required:
• With door leaf strengths greater than 50 mm: Obtain door cylinders of a greater length
(see tab 1), as well as spacer and longer screws if required
• Use the door half-cylinder 10/30 during fitting without the possibility of closing from
the outside
Table 1
Door panel
Cylinder dimensions in mm
thickness
(Dimension inside/Dimension outside)
in mm
135 – 50
30/60
151 – 60
30/70
161 – 70
30/80
171 – 80
30/90
181 – 90
30/100
191 – 100
30/110
101 – 110
30/120
40
Ø 3,0 mm
Ø 3,5 mm
Ø 5,0 mm
Ø 8,5 mm
Ø 10,0 mm
Ø 10,0 mm, length of at least 180 mm
Ø 6,0 mm
Ø 16,0 mm, for a wall lock
Ø 51–55 mm
Spacer discs with a thickness
of 10 mm, Quantity
–
1
2
3
4
5
6
Screws DIN 7984– 8.8
in mm
enclosed
enclosed
enclosed
M6 x 60
M6 x 60
M6 x 70
M6 x 70