curve
The heating curve must be adjusted to the geographical region
and the type of building in such way that it allows the indoor
temperature in the rooms to remain appropriate regardless of
any changes in the exterior temperature.
Heating curve should be set for each heating circuit. Slope
(steepness) of the curve can be adjusted. The slope should
be changed when the room temperature is too low, given the
outside conditions.
• Press the OK (D) button and "Time of day and date" will
appear on the display.
• Rotate the settings dial
circuit 1" Confirm the selection.
• Rotate the settings dial
curve slope" Confirm the selection.
• The currently set heating curve slope will flash.
• Rotate the settings dial
value (e.g. 0.80) and confirm the selection.
• Press the ESC button (C) to return to MAIN MENU.
(E) to highlight "Heating
(E) to highlight "Heating
(E) and set the desired