Error
7 red flashing lights
8 red flashing lights
At start-up, after
switch-off the white
LED, the LED flashes
3 times (red color)
(1 flash/second).
At start-up, after
switch-off the white
LED, the LED flashes
8 times (red color)
(3 flashes/second).
Permanent flashing of
the LED (red color)
(6 flashes/second).
Permanent flashing of
the LED (red color)
(3 flashes/second).
04/2014
Description
Battery voltage fault.
The tool does not start or
stops instantaneously.
Overcurrent on the power
circuit. The hardware
limit has been reached.
The tool does not start or
stops instantaneously.
Backup configuration has
been restored.
Main configuration has
been restored from the
backup configuration.
The tool switched to
default setting.
All configurations have
been corrupted.
Tool blocked.
Validation / Action
The fault means that the battery voltage is not
appropriate for the voltage announced in the
tool. Make sure that the tool is adapted for the
battery used. If the battery used is correct→
contact our customer service.
This problem can result from a use requiring
a too big power for the tool. If the fault still
appears, the power stage is faulty → contact our
customer service.
The user is not affected by this issue.
The tool can be used without restriction.
This error appears if the backup configuration
has been restored after corruption.
User not affected by this issue during normal
work.
If the user was updating the configuration of
the tool with the Speed Setting Module, it is
recommended to check the speed of the tool.
This error appears if the main configuration has
been restored after corruption.
The tool can be used but only with the default
parameters.
Speed and counters may be affected.
It is recommended to check the parameters
with the Speed Setting Module. If the problem
persist when the battery is plugged in, it is
recommended to replace the electronic board.
This alarm appears if the memory chip is out of
order.
The electronic board must be replaced.