14.4
Powermaster parameters
All Powermaster torches of the i-LTG/i-LTW – serie have two
free programmable parameter spaces (PL3 and PL4).
 Select sub parameter PL3 or PL4.
9 The 7-segment display 38 shows alternating code PL3 or
PL4 and the code of the selected Powermaster parameter.
 Select the required Powermaster parameter with the turn-
ing knob 41.
Parameter
Gas pre-flow time
Start current IS
of main current
Start current time
Upslope
of main current
Second current I2
representation in
Downslope
Final current IE
of main current
Final current time tE
Gas post-flow time
correction
Pulse frequency
0,2 - 2000 Hz
Pulse duty factor
Main current I1
AC-balance
positive welding
1
AC-frequency
1
Tab. 4:
Powermaster parameters
14.5
User-specific menu
 Switch off the equipment at the main switch 9.
 Press the selection button on the left 30 and keep it de-
pressed.
 Switch on the equipment at the main switch 9
9 The user-specific menu is activated. The menu item and its
set value are shown alternating in the 7-segment display
38
 Press the selection button 30 or 47 to switch among the
menu items.
 Turn the control dial 41 to change the set value.
1)
Only for AC/DC
- 40 -
Factory
Range
setting
0,1 - 10 sec
0,1
5 - 200 %
50
0 - 20 sec.
0,1
0 - 99 %
5
1 - 200 %
50
Amp.
0 - 99 %
20
5 - 200 %
25
0 - 20 sec.
0,2
20 - 500 %
100
5
1 - 99 %
50
10 - 90 %
35
current
30 - 200 Hz
60
1)
Menu
no.
C00
Display and adjustment of the torch-ID. See „Ad-
justment of the torch-ID" on page 41.
C01
Welding current limit for up/down torch. When
the welding current limit is switched to "On", the
welding current on the up/down torch cannot
be set higher than pre-selected on the control
terminal.
C02
Deactivation of the error message E05-00 (water
Code
pump) and of the water cooling unit by Lorch-
Net.
If the deactivation is switched "on", the error mes-
sage E05-00 (water pump) is no longer displayed.
Also the water cooling unit is not switched on by
LorchNet.
Practical, e.g. for the use of an automatic torch
without plug or a cooling unit without LorchNet.
C03
Activation of the orbital welding mode.
C04
ON: at short circuit the welding current don't
increase the adjusted welding current shown in
the display (set value).
Off: at short circuit the welding current is in-
creased on minimum 60 A.
C05
ON: by quick pressing of torch button 1 (start /
stop) the 2nd torch button is simulated.
(Second current on / off ). Useful e.g. for torches
with one button only.
C06
ON: the current decrease (downslope) will be - as
adjusted – conducted, also if the torch button is
released (4th tact).
Off: at earlier release of the torch button (4th
tact) the current decrease (downslope) is inter-
rupted.
C07
On: PE conductor monitoring activated
Off: PE conductor monitoring deactivated
the PE conductor monitoring is an optional avail-
able feature
C08
Off: Using a foot remote control, the minimum
current (independent from the adjusted welding
current) in the TIG mode / AC at
electrode-Ø 1,0...2,0 mm
electrode -Ø 2,4 mm
electrode -Ø 3,2 mm
On: the increased minimum current in the TIG-
mode / AC is deactivated
C10
Welding current limit
0 = Off
I1
...I1
Min
Max
Tab. 5:
User-specific menu
 Switch the equipment off at the main switch 9 to transfer
the settings from the user-specific menu.
909.2669.9-02
Menu item
= 10 Amps
= 15 Amps
= 20 Amps
= On
Starting up
Setting
values
9...45
On-Off
On-Off
On-Off
On-Off
On-Off
On-Off
On-Off
On-Off
0,
I1
...
Min
I1
Max