SLEEPING WELL OBLò
GENERAL DESCRIPTION
The air conditioner SLEEPING WELL OBLÒ allows to keep optimum thermal conditions inside the industrial vehicles' driving cabins during day
or night stops.
IT WORKS WHEN ENGINE IS SWITCHED OFF and is extremely quiet. It can be easily installed on any type of vehicle without alterations (with
existing roof hatch).
It uses R134a refrigerant (ecological refrigerant fluid).
TECHNICAL DATA
Cooling capacity
Evaporator air flow
N° ventilation speed
Working voltage
Power consumption
Refrigerant
Compressor
Functioning with engine off
Temperature's electronic control with digital control panel
Remote control
Weight
OPERATION / CONTROL PANEL
SLEEPING WELL OBLÒ CAN BE USED BY ACTIVATING THE AIR CONDITIONING OR THE FAN FUNCTION ONLY.
T0 : TEMPERATURE SET BY USER
Tamb : AMBIENT TEMPERATURE DETECTED BY PROBE
V1 : COMPRESSOR ROTATION SPEED (2500 Rpm)
V2 : COMPRESSOR ROTATION SPEED (4000 Rpm)
The basic operating principles of the central control unit are:
About 30" after switching on, the ventilation starts up automatically.
The AC system can run for a maximum of 6 hours.
The display always shows the temperature set by the user (T0).
The temperature which can be set by the user is between 17°C and 28°C.
ON / OFF - TIMER BUTTON OPERATION - TIMER (REF.A – SEE FIG.2)
ON / OFF function:
When the system is switched off, pressing down this button for more than 2 seconds, switches on the AC system.
If the system is switched on, pressing down this button for more than 2 seconds, switches off the AC system.
Timer function: (ref.a – see fig.2):
If the system is switched on, every time the TIMER button is pressed quickly, the system operation time is reduced by 1 hour.
MAX AC BUTTON OPERATION (OFFERS MAXIMUM PERFORMANCE BY THE SYSTEM) (REF.F – SEE FIG.2)
When the system is running, (by default in mode V
hours and the whole snowflake symbol will light up on the display (despite being usually only half lit at speed V
Once this function has been activated, press the MAX AC button again to return to speed V
By pressing the TIMER button with MAX AC engaged, the compressor running time at speed V
4 to 1 with steps of 1 hour.
Sleeping Well Oblò_01_06/2008
950 Watt / 3250 BTU
450 m3/h
6
24Vc.c
14,5A (max)
7,5A (standard)
R134a
Danfoss BD350 GH
YES
YES
YES
32 Kg
CONDITIONING (AC)
) press the MAX AC button to start rotation speed V
1
of the compressor for 4 consecutive
2
).
1
.
1
may diminish from
2
ENGLISH