ENGLISH
If the fan increase or reduction buttons are pressed (ref.c – see fig.2) when the system is switched off, only the evaporator fan is activated, with
the choice of 6 different speeds, shown on the central control unit display.
To switch off the fan it is necessary to set the value 0 on the central control unit display, using the fan speed reduction button.
The save-battery function starts when the power falls below a value of 21,5V.
In this case, the system (AC or VENT) shuts down, also deactivating the fan function and the message E1 appears on the display and the battery
symbol lights up.
When the power returns, for at least 10 seconds, to the value of 25V, the system is automatically reactivated, starting up the condenser fan,
followed by the evaporator fan and compressor.
Description
Battery voltage
(The battery-saver device has cut in. Voltage has fallen below the value of 21.5 V)
Fan over current cut-out
(The condenser or evaporator fan overloads the central control unit above the limited allowed. Possible cause:
short circuit or blockage of fan rotation.)
Compressor locked
(The rotor is locked or the pressure inside the cooling circuit is too high.)
Minimum compressor rotation speed
(If the cooling circuit is overloaded, the compressor cannot maintain the minimum rotation speed.)
High temperature on the central control unit
(If the cooling circuit is overloaded or the ambient temperature is high, the central control unit signals this
situation.)
Communication error
(There is no communication between the display and the central control unit.)
Temperature probe
(If the probe short-circuits or is not connected, the system stops.)
Tilt
(The system shut-down device installed to operate in the event of tilting has cut in. )
The remote control regulates both the conditioning function and the fan function.
Using the remote control it is possible to:
- Switch the system on and off (ref.a – see fig.2)
- Regulate the temperature (ref.b – see fig.2)
- Regulate the fan speed (ref.c – see fig.2)
- Engage the MAX AC function (ref.f – see fig.2)
- Modify the TIMER function (ref.a – see fig.2)

VENTILATION (FAN)
SAvE BATTERY FUNCTION (AC / FAN)
ERRORS SHOWN ON THE DISPLAY (AC / FAN)
REMOTE CONTROL
SLEEPING WELL OBLò
Message
Symbol
E1
E2
E3
E4
E5
E6
E7
E8