The electric overload protection (automatic circuit breaker with K-feature) must be equipped with a 30 mA safety switch (FI or RCD).
Three-phase current: 400 V (3P + N + PE), 50 Hz
Hoist control and electric connections
The hoist control and the connections must be dimensioned according to the wiring diagram.
In control systems for three-phase operation, equipment must be provided so that it shuts down the power in case of an incorrect
phase sequence to prevent a mix-up of the direction of travel UP/DOWN.
Determining the required cable cross-section:
In Illustration 19 determine the cable cross-section required for the code letter.
Determine the code letter (e.g. 'C') using Illustration 20. On hoists with two speeds the maximum rope speed is the determining
factor.