Illustration 15
If a radio remote control is installed, the additional space requirement of the receiver (11) must be considered, see Illustration 15.
Incorrect installation position!
Damage to the equipment may occur!
The equipment will be damaged if incorrect or insufficient lubricant is used!
–
The hoist must not be mounted horizontally on the flat side.
–
Attach the hoist in such a way that the flat side only points to the side.
The hoist can be anchored with and without an adapter (see pos. B in Illustration 13).
Anchoring without adapter:
at least 2 screws with self-locking nuts
Anchoring with adapter:
2 screws with self-locking nuts
Bolts of the same strength and equivalent locking can be used instead of the screws.
Observe the details in § 6.2.
4.6
Operating fluids
Application
Traction sheave external teeth (only model series X
2050)
Wire rope
Axle for the hand crank
4.7
Wiring diagram
The wiring diagram is located in the terminal box of the tirak™.
G1035.4 – 01/2019
Illustration 16
ATTENTION!
Lubricant
hebro-chemie VARILUB
or Klüber Grafloscon C-SG 0 Ultra
or Klüber C-SG 1000 Ultra
Quantity approx. 10 cm³ per lubrication
Multipurpose oil/grease (without disulphide)
Multipurpose grease