Description
The ZL160N control panel is suitable for con-
trolling an automatic system for the FLEX se-
ries swing gates powered by 24V d.c. with ca-
pacity up to 48W.
Designed and built entirely by CAME S.p.A. to
meet safety standards at an IP 54 protection
level. Housing in ABS.
Guaranteed 24 months, unless tampered with.
The circuit requires 230V (AC) on terminal blocks
L1 and L2, and is protected with 1.6A fuse,
whilst the low voltage command devices are
protected by a 3,15A fuse.
The accessories total capacity (24V) should not
exceed 40W.
The control panel includes an amperometric
sensor that constantly checks the force devel-
oped by the motor when opening or closing: if
this exceeds the preset level (for example, in
the event of an obstacle blocking movement), it
becomes operative and stops the motor.
Safety
Photocells can be connected to abtain:
- Re-opening during closure (2-C1), if the pho-
tocells identify an obstacle while the gate is
closing, they will reverse the direction of move-
ment until the gate is completely open;
- Total stop (1-2), shutdown of gate movement
without automatic closing, a pushbutton or radio
remote control must be actuated to resume
movement.
Optional accessories
- 12V Electric lock (2-ES);
- Gate open pilot lamp (3W max.). A lamp that
signals the gate's open position and that goes
out when the gate is in the closed position.
Connected to terminals 10-5;

GENERAL CHARACTERISTICS

- LB54 Board . Powers the reduction gears
through batteries in case of a power outage.
After the power supply is restored, it also re-
charges the batteries.
Other functions
- Automatic closing. The automatic closing timer
is automatically activated at the end of the
opening cycle. The preset, adjustable auto-
matic closing time is automatically interrupted
by the activation of any safety system, and is
deactivated after a STOP command or in case
of power failure;
- " Maintained action " . Gate operates only when
the pushbutton is held down (the radio remote
control system is deactivated). It is activated
when the T.L. trimmer is set to the minimum;
ment. At every opening command, the wings
press the closing stop-ledge for a second, thus
facilitating the release operation of the electric
lock connected to terminals 2-ES.
It is only active if the wings are closed and at
the end of the work time.
Adjiustments
- Automatic closure time;
- Operating time.
Important! Disconnect the unit from the
main power lines before carrying out any
operation inside the unit.
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
- Hammer move-
-3-