Herunterladen Diese Seite drucken

General Characteristics - CAME Z Serie Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Z Serie:

Werbung

Description of control panel
Control panel for 24V d.c. gear motors,
powered by 230V a.c. at 50-60 Hz (single-
phase).
Designed to control ATI, FERNI and FROG
gear motors.
Designed and built entirely by CAME
CANCELLI AUTOMATICI S.p.A., it meets
regulations in force and with IP 54 level of
protection.
Housing in ABS is equipped with vents to
provide internal air circulation. Guaranteed
24 months, unless tampered with.
This control panel is powered by 230V a.c.
across terminals L1 and L2, and is protected
by a 3.15A fuse on the main power line.
Control systems are powered by low voltage
and protected by a 315 mA fuse.
The total power consumption of 24V acces-
sories (which are protected by a 3.15A fuse)
must not exceed 40 W.
Safety
Photocells can be connected to obtain:
- Re-opening
Re-opening during the closing cycle (2-
C1), if the photocells identify an obstacle
while the gate is closing, they will reverse
the direction of movement until the gate is
completely open;
- Partial stop,
Partial stop, shutdown of moving gate,
with activation of an automatic closing cycle
(2-C3);
- Total stop
Total stop
T
otal stop
(1-2), shutdown of gate move-
ment without automatic closing; a pushbut-
ton or radio remote control must be actuated
to resume movement).
- Safety test function.
Safety test function. The control unit will
now check the safety system every time an
-4-

GENERAL CHARACTERISTICS

opening or closing command is given (see
p. 26).
The electrical panel includes an amperome-
tric sensor for the motors which is triggered
whenever an obstacle blocks movement du-
ring opening or closing. If operating speed,
the sensor inverts the movement direction.
If it is slowing down, one motor stops while
the other completes its movement. The sen-
sor's sensitivity can be adjusted using the
trimmers (see p.12).
The transformers are equipped with a
guard, which in case of thermal over load will
keep the doors open.
They are closed again only after the tem-
per a ture falls be low the emer gen cy thresh-
old.
Accessories which can be connected to
this unit
- "Gate open" signal light;
- Flashing signal light when gate is in motion
- Electric lock;
- LB18 circuit card for emergency battery,
which is automatically connected in case of
power failure; battery is recharged when line
power is restored
- Radiofrequency AF board (see table
pag.29).
Other functions available
- Automatic closing.
Automatic closing. The automatic closing
timer is automatically activated at the end
of the opening cycle. The preset, adjusta-
ble automatic closing time is automatically
interrupted by the activation of any safety
system, and is deactivated after a STOP
command or in case of power failure;
http://www.bakonline.net/
ENGLISH
amperome-

Werbung

loading

Diese Anleitung auch für:

Zl19