278 / 460
Bosch Rexroth AG
Information on this product
5.2.3.2
Partial front-panel view PSI 6xCx.xxx
24 V
output for power supply to I/O module (refer to page 367).
DC
24 V
output of the internal voltage source (refer to page 366).
DC
24 V
input for logic power supply (refer to page 365).
DC
Terminals for 24 V
voltage distribution (refer to page 368).
DC
Temperature-controlled 24 V
of external fans (refer to page 372).
24 V
output, e.g. for power supply to external consumers.
DC
Refer to Sect. 7.2.11 on page 373.
Terminals for "Main switch release" (refer to page 382)
Type-dependent: Analog output for force actua
ting variable. Refer to Sect. 7.2.12 from page 374.
Type-dependent: Digital (24 V
(0..10 V
) input for (force) feedback. Refer to
DC
Sect. 7.2.13 from page 375.
Type-dependent: Output for "Operate" signal output.
Type-dependent: Analog input for (force) feedback.
Refer to Sect. 7.2.13 from page 375.
Type-dependent: 0 V reference for output "Operate".
Measuring input for secondary current measurement.
Refer to Sect. 7.2.14 on page 377.
Type-dependent: Output/input for monitoring the
transformer temperature (refer to Sect. 7.2.15 on
page 380).
Measuring input for secondary voltage measurement
in the case of UI regulation. Refer to Sect. 7.2.17 on
page 384.
Connector for programming unit (for local programming)
(refer to Sect. 7.2.5 from page 363.
X3C: RS232 / V24 or alternatively
X3U: USB
DC LINK CIRCUIT LED:
Illuminated red if DC link voltage is present.
STATUS LED:
Illuminated yellow while the power unit is activated (weld
time)
Illuminated red if no firmware has been loaded or while
the timer is in "Boot" mode.
Type-specific: AnyBus module. E. g. for communication with a
programming terminal (BOS), connection of serial I/O to robot/
PLC (ProfiNet). For information on the modules and their LED
displays, refer to page 280 et seq. For installation/removal,
refer to page 416.
Battery for buffering the unit's internal RAM (for replacement of
battery, please refer to page 396).
Slot for licence memory card. Refer to page 418.
Diagnosis module, for fault display, fault reset, activating
the boot mode, weld timer reset.
(Refer to Sect. 5.2.4.8 on page 288.)
Fig. 8:Partial front-panel view PSI 6xCx.xxx
supply output for the supply/control
DC
) and analog
DC
X6M only for internal use
PSI 6xxx |
1070080028 / 08
X4
X5
X8
X2
X9
X3
X3C
X3U
X7E1
X6M