20 /
Error
E301
Communication
CVIPFlex software - No start flag on
the first byte of the frame.
E302
No
communication
Bluetooth module.
E404
Exceeding of the current threshold
forced in the power bus. Overcurrent
on the power circuit (software cut).
E405
Exceeding of the engine temperature
limit (80°C)
instantaneously.
E406
Exceeding of the internal handle
temperature (80°C) - The tool stops
instantaneously.
E407
Torque
transducer
fault. The measurement is out of
limits.
E410
ADC reference value measurement
error.
E411
Exceeding of the maximum engine
temperature (60°C);
completes the cycle in progress.
E412
Handle overheating.
E416
Engine temperature sensor faulty.
E417
DSP
board
faulty.
E418
No communication with the torque
transducer.
>E500
EEPROM access error.
E501
Error of data size sent to the EEPROM
E502
Reading error of CRC on "Identification - Tool - Calibration" parameters
E503
Reading error of CRC on "Code - Station - Sequence - Cycle" parameters
E504
Reading error of CRC on "Maintenance" parameters
E511
Reading error of "Identification - Tool - Calibration" parameters
Description
error
with
the
This could be due to a bug or interferences. Switch off the Bluetooth
radio of the CVIPFlex software, switch off the tool and re-start.
with
the
The tool does not work. The Bluetooth module is faulty, contact our
customer service.
The power programmed is too large for the tool. For instance you can
reduce the speed. Turn off the tool and turn it on again in order to reset
the fault.
Wait for the tool to cool down. The tool can tighten again when the
-
The
tool
stops
temperature is lower than 55°C. Usually this fault is preceded by the
E411 fault and only occurs when the engine temperature varies from less
than 60°C to more than 80°C in one cycle.
Wait for the tool cool down. The tool can tighten again when the
temperature is lower than 55°C. Usually this fault is preceded by the
E412 fault. It only occurs when the handle temperature varies from less
than 60°C to more than 80°C in one cycle.
compensation
A torque transducer compensation measurement (offset) is performed at
the beginning of each tightening. This fault means that the compensation
is out of limits by +/- 10% of the nominal load. That shows a torque
transducer zero drift. Make sure the tool is not under stress at the
beginning of the tightening.
DSP reference voltage is faulty. This leads to errors in the measurement
of engine position, temperature, mains voltage, mains current.
Wait for the tool to cool down. The tool can tighten again when the
the
tool
temperature is lower than 55°C. This means that the tool tightening rate
is too big or that the ambient temperature is higher than the usual
temperature. Make sure that the tightening rate is adapted to the
maximum tightening rate recommended by the manufacturer. Make sure
that the tightening parameters (final torque, joint stiffness) have been
optimised.
Never close up ventilation inlet, make sure the fan is in operation (a faint
noise is audible). The tool can tighten again when the temperature is
back to normal.
The temperature sensor on the hall board registers an abnormal
temperature (T<-10°C; T>110°C). The tool has stopped. Check the hall
board connection / change the hall board / contact our customer service.
temperature
sensor
The temperature sensor on the DSP board registers an abnormal
temperature (T<-10°C; T>110°C). The tool has stopped. Change the
DSP board / contact our customer service.
This error appears when the communication between the torque
transducer and the DSP is interrupted for any reason. It may be a flat
cable fault, a disconnection of the flat cable or a torque transducer
electronic fault.
The tool data are no longer available (EEPROM access faulty, data
partially or totally modified or lost). Contact our customer service.
EAP-TFlex tools