IO-Link interface (continued)
6.11

Stroke counter

6.11.1 Functional description

By specifying a position value (PW) and a symmetrical
span (SP) you can define up to three ranges within the
characteristic curve.
Each of these ranges can be enabled or disabled
separately (Mode).
Once the target has come to a stop in an active range, the
two stroke counters associated with the range are
incremented:
Counter Custom Operating: The counter can be reset
by the user.
Counter Total Operating: Non-resettable counter.
Fig. 6-6:
Function description (overview))
Since the individual counter ranges can also overlap,
stroke counters from more than one range may be
affected. In this case all the affected stroke counters are
incremented.
We recommend setting the stroke counters in increasing
order, but this is not absolutely necessary.
22
english
(no tool, chuck open)
Range 2
(tool clamped)
Range 1
(no tool, chuck
closed)
Span 2
Position value 1
Span 1
Range 3
Position value 3
Span 3
Position value 2