BIP LD2-T017-01-EP _ _ / EP _ _ -S4
Inductive Positioning System
6
IO-Link interface (continued)
6.8
Switching Signal Channels, SSC
With the BIP sensor you can program four independent
switching states (Switching Signal Channels, SSCs).
Each switching signal is configured using profile-specific
parameters (see Tab. 6-10). Configuring the switching
channel begins by setting the channel using Index 0x003A.
Index
Parameters
0x003A
Teach-In Channel
Setting
0x003B
Teach-In Status
0x003C
Set Point value
(SSC1)
0x003D
Switching Signal
configuration SSC1
0x003E
Set Point value
(SSC2)
0x003F
Switching Signal
configuration SSC2
0x4000
Set Point value
(SSC3)
0x4001
Switching Signal
configuration SSC3
0x4002
Set Point value
(SSC4)
0x4003
Switching Signal
configuration SSC4
Tab. 6-10: Profile-specific parameters
www.balluff.com
Subindex
Parame-
Data format
ters
0x00
0x00
0x01
Setpoint1
0x02
Setpoint2
0x01
logic
0x02
mode
0x03
hysteresis
0x01
Setpoint1
0x02
Setpoint2
0x01
logic
0x02
mode
0x03
hysteresis
0x01
Setpoint1
0x02
Setpoint2
0x01
logic
0x02
mode
0x03
hysteresis
0x01
Setpoint1
0x02
Setpoint2
0x01
logic
0x02
mode
0x03
hysteresis
Based on the Smart Sensor profile the Parameter
Switching Signal configuration can be used to set the
behavior of the switching points:
–
Single-point mode, (Fig. 6-2): Value: 1
–
Two-point mode, (Fig. 6-3): Value: 3
–
Windowed mode, (Fig. 6-4): Value: 2
Switching signals can only be taught as long as
the position value is valid.
Access
Data
UINT8
R/W
0x01: SSC1
0x02: SSC2
0x03: SSC3
0x04: SSC4
UINT8
R
INT16
R/W
–32000...+32000
INT16
R/W
–32000...+32000
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
INT16
R/W
50...16900 μm
INT16
R/W
–32000...+32000
INT16
R/W
–32000...+32000
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
INT16
R/W
50...16900 μm
INT16
R/W
–32000...+32000
INT16
R/W
–32000...+32000
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
INT16
R/W
50...16900 μm
INT16
R/W
–32000...+32000
INT16
R/W
–32000...+32000
UINT8
R/W
0x00 : normal mode
0x01: inverted mode
UINT8
R/W
0x01: Single point
0x02: Window mode
0x03 Two Point mode
INT16
R/W
50...16900 μm
english
17