3 Product description
NOTICE
The generator must generate at least 30% more power than the maximum power output of the device.
Example: 13 kVA (device) + 30% = 17 kVA. A 17 kVA generator must be used for this device. A smaller
generator must not be used, as this will result in damage to the Jäckle & Ess welding device and to the
generator itself.
3.2 Ambient conditions
The welding power source must only be operated at a temperature between −10 °C and +40 °C and at
a relative air humidity of up to 50% at +40 °C or up to 90% at +20 °C. The ambient air must be free of
unusually high quantities of dust, acids, corrosive gases or substances etc., other than those that arise during
the welding process.
3.3 Nameplate
The welding power source is labelled with a nameplate on the housing as follows:
Fig. 2
Fig. 3
EN - 4
maxiMIG 250 nameplate
maxiMIG 300 nameplate
maxiMIG 250/300