5

MOUNTING

5
Mounting
6

Electrical installation

6
Mount the sensor using a suitable mounting bracket (see the SICK range of acces‐
sories).
Figure 1: Alignment of the sensor relative to the object direction
Note the sensor's maximum permissible tightening torque of < 0,4 Nm.
Note the preferred direction of the object relative to the sensor, cf.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Pin assignment
Cable: Wire color
Only apply voltage/switch on the voltage supply once all electrical connections have
been established.
Explanations on connection diagram.
BN = brown
WH = white
BU = blue
BK = black
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = Test input
U
: 10 ... 30 V DC
B
Table 2: Electrical connection
x4
1 = BN
4
2 = WH
3 = BU
4 = BK
1
x2
xH
3
2
4
0.14 mm
AWG26
1
3
2
see figure 1, page
x1
xG
4
0.14 mm
2
AWG26
1
3