Problem
Temperature
sensor reads too
high in the day
time.
Relative pressure
does not agree
with official
reporting station
Rain gauge reports
rain when it is not
raining
Data not reporting
to Wunderground.
com
Solution
Make certain that the sensor array is not too close
to heat generating sources or strictures, such as
buildings, pavement, walls or air conditioning
units.
Use the calibration feature to offset installation
issues related to radiant heat sources. Reference
Section 6.7.
You may be viewing the absolute pressure, not the
relative pressure.
Select the relative pressure. Make sure you
properly calibrate the sensor to an official local
weather station. Reference Section 6.7 for details.
An unstable mounting solution (sway in the
mounting pole) may result in the tipping bucket
incorrectly incrementing rainfall. Make sure you
have a stable, level mounting solution.
1. Confirm your password or key is correct. It
is the password you registered on
Wunderground.com. Your
Wunderground.com password cannot
begin with a non-alphanumeric character
(a limitation of Wundeground.com, not the
station). Example, $oewkrf is not a valid
password, but oewkrf$ is valid.
2. Confirm your station ID is correct. The
station ID is all caps, and the most
common issue is substituting an O for a 0
(or visa versa). Example, KAZPHOEN11,
not KAZPH0EN11
3. Make sure the date and time is correct on
the console. If incorrect, you may be
reporting old data, not real time data.