Notes about the ingredients (REACH)
You will find current information about the
ingredients at:
www.kaercher.com/REACH
Before Startup
Unpacking
Check the contents of the pack before
–
unpacking.
In case of transport damage inform ven-
–
dor immediately
Check oil level
Read the oil level display when the de-
vice is not running. The oil level must be
above the two pointers.
Activate deaeration of oil container
Unscrew the fastening screws of the
device hood; remove the device hood.
Cut off tip of oil container cover
Fasten the device hood.
Attaching the Accessories
Mount the nozzle on the spray pipe (mark-
ings on the adjustment ring at the top).
Connect ray tube to hand spray gun
Note
Only with HD 7/10 CXF:
When space is limited, the enclosed adapt-
er with nozzle can be mounted directly to
the hand spray gun.
In devices without hose drum:
Loosen the clamps of the pushing handle.
Adjust the handle to the desired height.
Tighten the clamps of the pushing handle.
Fasten the high pressure hose to the
high pressure connection.
In devices with hose drum:
Insert the crank in the hose drum shaft
and lock it in.
Before rolling up, stretch out the high
pressure hose.
Wind the high pressure hose in uniform
layers on the hose drum by rotating the
crank. Select the rotation direction in
20
such a way that the high pressure hose
does not get bent.
Electrical connection
Danger
Danger of injury by electric shock.
The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an
electrical supply which has been installed in
accordance with IEC 60364.
The voltage indicated on the type plate
must correspond to the voltage of the elec-
trical source.
The minimum fuse rating required at the
socket outlet is (see technical specifications).
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
The appliance should always be connected
to the electrical mains using a plug. It is for-
bidden to permanently connect the appli-
ance to the power supply. The plug is only
for mains separation.
Check the power cord with mains plug for
damage before every use. If the power cord
is damaged, please arrange immediately
for the exchange by an authorized custom-
er service or a skilled electrician.
The plug and coupling of the extension ca-
ble used must be watertight.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
Unsuitable electrical extension cables can
be hazardous. Only use electrical exten-
sion cables outdoors which have been ap-
proved and labelled for this purpose and
have an adequate cable cross-section:
For connection values, see type plate/tech-
nical data.
– 3
EN
Start up