Notes about the ingredients (REACH)
You will find current information about the
ingredients at:
www.kaercher.com/REACH
Before Startup
Attaching the Accessories
Attach the wheel caps.
Note: The EASY!Lock system joins com-
ponents with a quick-fasten thread solidly
and securely with just one turn.
1.
Mount the nozzle on the spray lance
(marking on the adjustment ring at the
top) and hand-tighten it (EASY!Lock).
Join the spray lance with the trigger gun
and tighten until hand-tight
(EASY!Lock).
Release the unlocking device of the
push handle.
Pull the push handle out to its end position.
In devices without hose drum:
Join the high-pressure hose with trigger
gun and high-pressure connection of
the appliance and tighten until hand-
tight (EASY!Lock).
In devices with hose drum:
Insert the crank in the hose drum shaft
and lock it in.
Before rolling up, stretch out the high
pressure hose.
Wind the high pressure hose in uniform
layers on the hose drum by rotating the
crank. Select the rotation direction in
such a way that the high pressure hose
does not get bent.
Join the high pressure hose with trigger
gun and tighten until hand-tight
(EASY!Lock).
20
2.
EN
Start up
WARNING
Risk of injury! Appliance, accessories, sup-
ply lines and connections must be in fault-
free condition. If they are not in a perfect
state then the appliance must not be used.
Electrical connection
DANGER
Danger of injury by electric shock.
– It is imperative to connect the appliance
to the electric mains by means of a plug.
It is forbidden to permanently connect
the appliance to the power supply. The
plug serves for the disconnection from
the mains.
– The plug and coupling of the extension
cable used must be watertight.
– Use the extension cord that has an ade-
quate cross-section (see "Technical Data")
and unwind it fully from the cable drum.
For connection values, see type plate/tech-
nical data.
Unwind the mains cable and place it on
the floor.
Insert the mains plug into a socket.
Water connection
Connection to the water supply
WARNING
Observe regulations of water supplier.
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. A suit-
able system separator by KÄRCHER or al-
ternatively a system separator according to
EN 12729 type BA must be used.
Water that was flowing through a system
separator is considered non-drinkable.
CAUTION
Always connect the system separator to
the water supply, never directly to the appli-
ance!
For connection values refer to technical
specifications
Connect the supply hose (min. length 7.5
m, minimum diameter 1/2") to the water
connection point of the machine and at the
water supply point (for e.g. a tap).
– 3