Operator console
1 Rotating button for drive speed
(B 40 W only)
2 Intelligent Key
yellow - operator
grey - supervisor
3 Display
4 Program selection switch
5 Info button
Program selection switch
1 OFF
Device is switched off
2 Transport mode
(B 40 W only)
Driving to the Place of Use.
3 Eco mode
Wet clean the floor (with reduced brush
speed) and vacuum up wastewater
(with reduced suction).
4 Normal mode
Wet clean the floor and vacuum up dirt
water.
5 Intense mode
Wet clean the floor and allow the deter-
gent to react.
6 Vacuum mode
Suck in the dirt fleet.
7 Polishing mode
Polishing the floor without the applica-
tion of liquid.
16

Before Startup

Installing the Brushes
BD model
The disc brush must be installed before the
initial operation (see "Maintenance work").
BR model
The brushes are mounted.
Install batteries
Install the batteries (see "Care and Mainte-
nance/Install and connect batteries").
Setting the charging marker line
Prior to the initial startup, following a ser-
vice reset or when switching to another bat-
tery type, you must adjust the charging
marker line.
 Use the Grey Intelligent Key.
 Setting the charging marker line (see
Chapter "Grey Intelligent Key/Setting
the charging marker line".
Using batteries made by other
manufacturers
We recommend using our batteries as de-
scribed in chapter "Care and Maintenance/
Recommended batteries".
Note:
When using other batteries (e.g. of other
manufacturers) the total discharge protec-
tion for the respective battery must be read-
justed.
Charging battery
Note:
The device is equipped with a safety mech-
anism to prevent total discharge, i.e. when
the permissible minimum capacity is
reached, the brush motor and the turbine
are switched off.
 Drive the machine directly to the charg-
ing station; avoid any steep gradients in
the process.
DANGER
Danger of injury due to electric shock. Ob-
serve the mains voltage and fuse protec-
tion on the type plate of the device.
Only use the charger in dry rooms with suf-
ficient ventilation!
Charging process
– Average charging time is approx. 10 -15
hours.
– The built-in charger has electronic con-
trols and is suitable for all recommend-
ed batteries; it automatically switches
off the charging process.
– The built-in battery is shown on the dis-
play during the charging process. If this
is not the case, the charging marker line
must be selected (see "Setting the
charging marker line").
– The appliance must not be used during
the charging process.
Initial charge tips
With the initial charge, the control will not
yet be able to detect which battery type has
been installed. Keep charging the batteries
until the display shows a full charge
DANGER
Risk of explosion!
3
-
EN
Prior to Charging low-maintenance bat-
teries, the tank must be swivelled upwards
(see chapter "Installing and connecting bat-
teries"). This will prevent the generation of
dangerous gases during the charging pro-
cess under the tank.
While the water tank is folded up, you must
not clean with any water.
When charging maintenance-free batter-
ies, the water tank does not need to be
folded up.
 Insert the plug of the connecting cable
into the socket. The charging process
will start.
Note: The selected battery will be dis-
played during charging.
 Charge until the display shows a full
charge.
Low maintenance batteries (wet
batteries)
WARNING
Danger of causticization!
– Adding water to the battery in its dis-
charged state can cause the acid to
leak.
– Use safety glasses while handling bat-
tery acid and follow the safety instruc-
tions to avoid personal injury or damage
to clothes.
– Should the acid spray on to the skin or
clothes, rinse immediately with lots of
water.
ATTENTION
Risk of damage!
– Use only distilled or desalinated water
(EN 50272-T3) for filling the battery.
– Do not add any substances (so-called
performance improving agents), else
warranty claims will not be entertained.
– Replace batteries with the same battery
type only. Otherwise the charging char-
acterisitc must be readjusted by the af-
tersales service.
Installing the Vacuum Bar
 Insert the vacuum bar into the vacuum
bar suspension in such a manner that
the profiled sheet is positioned above
the suspension.
 Tighten the wing nuts.
 Insert the suction hose.
Unloading
DANGER
Risk of injury. Pull the Intelligent Key to take
all functions out of operation immediately.
 Insert batteries and connect (see "Be-
fore Start-up").
 Place long lateral boards of the packag-
ing as a ramp next to the pallet.