7.7.3.5 Attribute 0x05, Interface Configuration

The Interface Configuration attribute contains the configuration parameters
required to operate the measuring system as a TCP/IP node. In order to prevent
incomplete or incompatible configuration, the parameters making up the Interface
Configuration attribute cannot be set individually. To modify the Interface
Configuration attribute, the user should first Get the Interface Configuration
Attribute, change the desired parameters then set the attribute.
Name
IP address
Network mask
Gateway address
Name server
Name server 2
Domain name

7.7.3.5.1 Obtaining of the IP parameter

In the start-up phase of the measuring system the stored configuration from "Attribute
0x05, Interface Configuration" (page 137), the stored value from "Attribute 0x03,
Configuration Control" (page 136) and the value of the hardware switches (page 91) is
read and is evaluated as follows:
Config. Control
0x00
0x01 ... 0xFE
-
-
0x02
other
Printed in the Federal Republic of Germany
06/15/2020
Description
Sets the device's IP address
Sets the device's Subnet mask
Sets the device's default Gateway
0, not supported
0, not supported
0, not supported
Switch
Action
0x00
FLASH active
Switch active
0xFF
DHCP request
0x00
-
none
TR - ELE - BA - DGB - 0031 - 01
Description
Configuration is obtained from the FLASH.
IP address: 192.168.1.<Switch position>
Subnet mask: 255.255.255.0
Default Gateway: 192.168.1.254
Configuration is obtained from a DHCP
server. The DHCP requests are only
stopped if a response was received.
Prohibited!
Request is answered with error code 0x20.