BTL7-A/C/E/G_ _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/S140/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
4
Installation and connection (continued)
4.4.3
Connector type S135
S135
-A_10
-G_10
Pin
1
0...10 V
-10...10 V
2
3
10...0 V
10...-10 V
4
0 V (pin 3)
BTL7-_1_ _-...
5
20...28 V
6
GND
Tab. 4-4:
Connection assignment BTL7...-S135
4.4.4
Connector type S140
S140
Pin
-A_10
-G_10
A
B
Not used
1)
C
10...0 V
10...–10 V
F
G
H
J
0...10 V
–10...10 V
K / E
BTL7-_1_ _-...
D
20...28 V
Tab. 4-5:
Connection assignment BTL7...-S140
12
english
-C_00
-C_70
0...20 mA
20...0 mA
0 V (pin 1)
Not used
Not used
BTL7-_5_ _-...
2)
Interface BTL7-...
-C_00
-C_70
0 V
0...20 mA
20...0 mA
Not used
GND
2)
La (programming input)
Lb (programming input)
Not used
Not used
1)
BTL7-_5_ _-...
-E_00
-E_70
4...20 mA
20...4 mA
Fig. 4-11: Pin assignment of S135 (view of
1)
1)
Unassigned leads can be connected to the GND
1)
on the controller side but not to the shield.
10...30 V
Reference potential for supply voltage and
2)
GND
2)
EMC-GND.
-E_00
-E_70
4...20 mA
20...4 mA
Fig. 4-12: Pin assignment of S140 (view of
1)
1)
Unassigned leads can be connected to the GND
on the controller side but not to the shield.
2)
Reference potential for supply voltage and
1)
EMC-GND.
10...30 V
connector pins of BTL), 6-pin M16
circular plug
G
F
K
H
J
A
E
C
B
D
connector pins of BTL), 10-pin circular
plug