OPERATION
The stove has two operating modes:
- MANUAL:
In the MANUAL operating mode, the stove's operating power
is set, independently of the temperature in the room where it is
installed. To select the MANUAL operating mode press the
left knob and set the desired ambient temperature
(SET TEMP-ROOM) over 40 ° C, by turning the knob itself
or by using the + / - buttons. "MAN" will be shown on the di-
splay. Press and then turn the right knob or use the + / - buttons
to change the stove's power; press the knob again or the ON/
OFF button to confi rm the power selected.
AUTOMATIC
In the AUTOMATIC operating mode,
it is possible to set a target temperature for the room in which
the stove is installed.
The stove automatically moves to power 1 when the desired
ambient temperature is reached (SET TEMP-ROOM).
The desired ambient temperature can be changed
(SET TEMP-ROOM) by pressing and turning the left knob or
by using the +/- buttons.
Press the knob again or the ON/OFF button to confi rm.
The ventilation is always correlated to the power in use, so it
cannot be changed.
Panel On/Off button
Switches the stove on or off.
Within the menu, the On/Off button is used to return to the
previous menu or to exit the current mode.
Panel +/- button
Increases or decreases the values that appear in the various
operating modes.
Panel "reserve" button
Function to determine the amount of pellets remaining in the
hopper. This function can be enabled or disabled through the
user's menu, "reserve variation". If the "reserve" button is
pressed, a default value of 15kg will be added.
The value can be modifi ed, accessing the "reserve variation"
user's menu; press the '+' or '-' buttons to increase
or decrease this value by a minimum of 5 Kg up to a maximum
of 15 Kg (if a value of 5 Kg is set, 5 Kg will
be added every time the "reserve" button is pressed).
In case of an error, press the '-' to go back.
INSTRUCTIONS FOR USE
Panel
button
Informs the user of the stove's status; if pressed within the
menus it displays the previous menu/parameter.
LT knob
FILLING THE FEED SCREW
(only if the stove has no pellets)
To load the feed screw, access the USER'S MENU,
go to "INITIAL LOAD" and press the button
This should only be done with the stove off and completely
cooled.
IGNITION
Automatic ignition
With the stove on stand-by (with the word "TURNED OFF"
shown on the display), press the on/off button for 2 sec to start
the ignition process; the word 'IGNITION PHASE-PRELO-
ADING' (time during which the quantity of pellets necessary
for ignition is loaded ) is shown on the display followed by
'IGNITION PHASE' (time from which the glow plug is ignited
and the fl ame is detected) and then 'IGNITION PHASE-
WAIT FLAME' (time for which the stove awaits detection of
the fl ame).
When the fl ame is detected, the electrical resistance switches
off and the word "STABILIZATION" (time in which the stove
monitors the increase in smoke temperature, which must incre-
ase by no more than 2 degrees per minute otherwise an alarm is
triggered) appears on the display; once stabilization is complete
and all the tests are positive, the word "WORK" appears on the
display.
This procedure takes approximately 15 minutes.
Shutdown
With the stove operating press the ON/OFF button for 2 sec to
start the AIR FANS shut-down procedure (air fans operating,
motor gear off, smoke extractor operating), and the message
"STOVE IN SHUTDOWN MODE' will be displayed; this
procedure takes a minimum of 15 minutes.
If, after this time has passes, the stove's temperature exceeds
the shutdown threshold, the procedure will continue until rea-
ching this threshold.
If the stove is blocked, see the alarms on page 14-15 or contact
your local dealer or Authorised Service Centre (CAT).
USER'S MENU
A 'USER'S MENU' is present within the display, whose fun-
ctions must be modifi ed via the CAT.
- 24
-
panel
RT knob
.