Main working parts (Fig. 10)
A) Internal laser measuring sensor
B) External laser measuring sensor
C) Telecamera
D) Touchscreen LCD monitor
E) LED light
F) Confirmation button
G) Side flange holders
H) Bushing holder
I) Wheel support shaft
L) Wheel guard
M) Control pedal C of the automatic wheel
clamping system
48
The wheel balancer is set up by the manufacturer
to operate with the power supply available in the
place of installation. The set-up data for each
machine are given on the machine data plate and
on a special label attached to the power supply
connection cable.
Any operations for hooking up to the workshop
electrical board must be carried out only by
qualified technicians in compliance with the
regulations in force, under the responsibility
and at the charge of the customer.
The electrical hook-up must be performed ac-
cording to:
9
• Absorbed power specifications indicated on
the machine data plate.
• The distance between the machine and the
electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when
starting up) of the rated voltage specified on
the data plate.
- The user must:
• Connect the machine to a dedicated electrical
power socket equipped with its own differential
circuit breaker with a sensitivity ‡ 30mA.
• Power line fuses in accordance with specifica-
tions in the main wiring diagram of this manual.
• Provide the workshop electric installation with
an efficient grounding circuit.
- To prevent unauthorised use of the machine,
always disconnect the power supply plug when
the machine is not used (switched off) for ex-
tended periods of time.
- If the machine is connected directly to the power
supply by means of the main electrical panel
and without the use of a plug, a key-operated
or padlockable switch must be installed to
restrict machine use exclusively to qualified
personnel.
A good grounding connection is essential for cor-
rect operation of the machine. NEVER connect the
machine ground wire to a gas pipe, water pipe,
telephone cable or any other unsuitable object.
10
EYELIGHT Plus DiagnosticLine - Operator's manual

ELECTRICAL HOOK-UP

WARNING
WARNING