CONNECTING THE HEAT PUMP TO THE POWER SUPPLY
NETWORK
Fig. 7: Protective cover
Fig. 8: Electrical circuit diagram
Legend:
T1 - Bar with sensors
T2 - Outlet heating water temperature sensor
T3 - Inlet heating water temperature sensor
2 - Compressor
3 - Flow switch
Before connecting to the power supply network, install
a power supply cord in the heat pump, with a min.
2
diameter of 1.5 mm
this, remove the protective cover from the heat pump.
The cover is attached using two screws (Fig. 7).
Connecting the heat pump to the power supply network
must take place in accordance with the standards for
electric appliances. To comply with the national
installation regulations, an all poles disconnect switch
must be installed between the heat pump and the
power supply network.
5 - Electric heating element (2 x 1000 W)
6 - Thermal cut-out
7 - Magnesium anode
8 - LCD touch screen
9 - Boiler - ground
10 - Housing - ground
(H05VV-F 3G 1.5 mm
2
). To do