EN
/i
Hydraulic couplers
Dust caps
Hydraulic hoses
Light
Blades
Snap ring of hinge pin
Centre bolt
Hinge pins
Accessories and lock pins
Carrying handle
Deadman's handle
8.5
Maintenance activities
8.5.1
General
•
After every use:
1. Check the operation of the tool.
2. Check the tool for damage and leaks. If the tool does not work properly and/or leaks, have it
repaired by a Holmatro Certified Technician.
8.5.2
Hydraulic hoses
WARNING
Check that the hose bend restrictors are in place and in good condition.
•
Check the hose for damage and leaks. Replace the hose if it leaks, has kinks, the reinforced cover
is visible or it has blisters or bulges higher than 1 mm. In case of doubt always contact the Holmatro
dealer who can assess the seriousness of the damage.
•
Replace the hose no later than 10 years after the date of manufacture, regardless of its use and
external appearance. The date of manufacture is part of the test code, the first 4 digits of the test
code specify the date of manufacture of the hose (yymm*****).
8.5.3
Hydraulic couplers
•
Check the couplers for damage. Have a Holmatro Certified Technician replace damaged couplers.
46
Check, clean, lubricate
Check, clean, lubricate
Check
Check
Check, clean, lubricate
Check
Lubricate
Check
Lubricate
Check
Check
Check
916.001.554_002
Time interval
x
x
x
x
x
x
x
x
x
x
x
x
x
CT51** (RH)(ST)