iROB
7.1 Operating elements
7.1.1 iROB robot welding power source
1
1
Switchable digital display
2
Power supply LED
3
General alarm LED
Fig. 7
Front view
Symbol
Pos. Designation
(1)
Allows display of wire feeder speed, recommended material thickness, welding current.
(2)
Lit when the robot welding system has been connected to the power supply and is on.
(3)
The error message is shown on the digital displays.
10 Troubleshooting on page EN-21
(3)
Lit when voltage has been applied to the output terminals of the system.
(5)
Switches the parameters in (1) .
(5)
Switches on the system. Has two positions: "O" OFF, "I" ON.
(6)
Resets the error message when an alarm occurs.
2
3
9
4
Welding current On LED
5
Parameter selection trigger
6
Main switch
4
5
6
7
8
7
RESET trigger
8
Connection iCONTROL
9
Welding voltage digital display
7 Operation
EN - 17