5.4 Opening the device
T
T
WARNING
There is the risk of being crushed when the enclosure is
open
There are sharp edges below the front panel. Closing the
hatch may cause severe injuries.
f Never put your hand in the opening bracket.
Fig. 5: Opening the device
f Ensure that the power supply is switched off.
f Open the lock on the front side using the key.
f Swing the front panel upwards.
f Secure the front panel to prevent it from closing of its
own accord.
1
2
5.5 Mounting the device
2
Fig. 6: Remove covers
f Loosen the four screws below the front panel.
The screws need not be removed entirely for this pur-
pose.
f Remove the two covers above and below.
MENNEKES recommends mounting at an ergo-
nomically sensible height depending on the
height of the body.
1
9
EN