No.
1
Stroke display, entry of the height for the display in an
extended state.
2
Basic height, entry of the height for the display in a
retracted state. 0 – Display in percent.
3
Unit, entry of the unit for the display: 0 - %; 1 – cm; 2 –
mm; 3 – inch.
4
Safety edge: 0 – deactivate; 1 – activate
5
External stop input: 0 – deactivate; 1 - activate
6
SyncBUS address: 0 – Bus deactivated; 1 – Master; 2,...,8 -
Slaves
11
Nominal speed in increments/seconds. Danger of
contouring errors at excessive nominal speed.
12
Acceleration in increments/second².
MultiControl II duo and MultiControl II quadro assembly instructions
• Press function key 2 to transfer the settings for the control to the
memory of the hand switch.
• Remove the hand switch from the control. Connect it to the control
which you wish to copy the settings to.
• Select the "Control" → "Parameter" → "Copy parameter" menu item.
Afterwards, the display will once again show the graphics that you can
see in Figure 16.
• Press function key 1.
-›› The settings have now been copied to the control.
6.5.6.14 Changing parameters
The
settings
for
directly
changing
→ "Parameter" → "Change parameter" menu item. You can only access the menu
after entering a password. You can obtain this password upon request (see chapter 1 for
contact information).
Now enter the corresponding no. of parameter using the arrow keys and function
key 2. Adapt the parameters as you desire and confirm the entry with function
key 2. Please note that confirmation can only be made after reaching the last
digit on the right side of the display.
The following parameters can be adjusted:
Parameter description
the
control
can
the
parameters.
also
be
adjusted
Open
the
Default
Min.
(MLII)
1
1
0
0
0
0
0
0
0
0
0
0
360
2
720
100
by
"Control"
Max.
9999
9999
3
1
1
255
1000
5000
115