Hydraulic system data
Maximum drive system pressure
Maximum accessory system pressure
Hydraulic system oil (at ambient temperature above 10°C)
NOTE
If the machine is to be used at ambient temperatures below 10°C, the oil should be replaced with equivalent oil having a
viscosity of 32 cSt. For temperatures below 0°C, use oil with lower viscosity.
(****)
See the below hydraulic system oil technical data and reference data tables.
SPECIFICATIONS
AGIP ARNICA
Viscosity at 40°C
Viscosity at 100°C
Viscosity index
Flash point COC
Pour point
Density at 15°C
Climate control system data (optional)
Gas type
Gas quantity

ENVIRONMENTAL CONDITIONS

In the environment where the machine operates, there must not be any danger of explosion.
To avoid inhaling exhaust gas, the machine must be used only where there is a proper air change.
The machine operates correctly (*) in the following environmental conditions:
Temperature: -10°C to +40°C
Humidity: 30% to 95%
(*)
When using the sweeper at a temperature between -10°C and 0°C the dust control system cannot be used; moreover the
water tanks and the dust control system itself must be empty.
46
32
mm²/s
45
32
mm²/s
7.97
6.40
/
150
157
°C
215
202
°C
-36
-36
kg/l
0.87
0.865
RS 501
33015501(3)2008-02 A
USER MANUAL
Values
250 Bar
120/200 Bar
AGIP Arnica 46 (****)
REFERENCE DATA
ISO-L-HV
ISO 11158
AFNOR NF E 48603 HV
AISE 127
ATOS Tab. P 002-0/I
BS 4231 HSE
CETOP RP 91 H HV
COMMERCIAL HYDRAULICS
Danieli Standard 0.000.001 (AGIP ARNICA
22, 46, 68)
EATON VICKERS I-286-S3
EATON VICKERS M-2950
DIN 51524 t.3 HVLP
LAMB LANDIS-CINCINNATI P68, P69 and P70
LINDE
PARKER HANNIFIN (DENISON) HF-0
REXROTH RE 90220-1/11.02
SAUER-DANFOSS 520L0463
Values
Reclin 134a
0.8 kg
ENGLISH