Safety
The manufacturer does not accept liability for damage
resulting from non-observance of the overall documenta-
tion.

2.1 Intended use

Observe all provisions included in the operating instruc-
tions.
Observe all safety instructions.
Comply with inspection and maintenance intervals.
Use the pump/aggregate exclusively for delivery of the
permissible media to be pumped
( General technical data, page 27).
Observe the operating limits and the minimum flow rate
depending on size.
Prevent dry running:
The mechanical seal will be damaged within only few
seconds.
Ensure that the pump/aggregate is only operated with
sufficient medium to be pumped, never without me-
dium to be pumped.
Prevent cavitation:
Completely open the suction-side fitting and do not use
it for controlling the flow rate.
Do not open the pressure-side fitting beyond the
agreed operating point.
Prevent overheating:
Do not operate the aggregate when the pressure-side
fitting is closed.
Observe the minimum flow rate
(General technical data, page 25).
Prevent motor damage:
Do not open the pressure-side fitting beyond the
agreed operating point.
Observe the switching frequency of the aggregate.
The motor protection switch must not be set to a value
above nominal current.
Any use other than the intended use must be agreed with
the manufacturer.

2.2 Potential misuse

Observe the operating limits of the pump/aggregate con-
cerning temperature, pressure, speed, flow rate, density
and viscosity ( Operating limits, page 25).
The higher the density of the medium to be pumped, the
higher the motor power consumption. Observe the permis-
sible density to protect the aggregate against overload.
Lower densities are permissible. In this case, adjust the
auxiliary systems accordingly.
Refrain from delivering abrasive and solid laden liquids.
Do not combine multiple limit values
( Operating limits, page 25).
Prevent sudden temperature changes of the medium to be
pumped.
Do not use in rooms where explosive gases may be present
unless the pump/aggregate has been expressly intended
for such purpose.
Do not extract, deliver or compact explosive, inflammable,
aggressive or toxic media unless the aggregates have been
expressly intended for such purpose.
Unauthorized opening of the pump/aggregate results in the
forfeiture of any and all claims for defects.
05/2011
1096.0833 | CY, CSY, LNY, LSY, NPY, PY, Y, YS Series

2.3 General safety instructions

The following provisions must be observed prior to execut-
ing any works.
2.3.1

Product safety

The pump/aggregate has been designed in accordance with
state-of-the-art technology and the generally acknowledged
rules on safety.
Yet, operation of this pump/aggregate may present a threat to
the life or physical health of the user or third parties and impair
the pump/aggregate and other property.
Only operate the pump/aggregate in a technically flawless
condition and in accordance with the provisions, safety pre-
cautions and warnings included in these operating instruc-
tions.
Keep these operating instructions as well as all supplied
documents complete and legible and ensure that they can
be accessed by staff at all times.
Refrain from any operating methods which may put staff or
uninvolved third parties at risk.
In case of defects having safety implications:
shut down the aggregate immediately and consult the per-
son in charge to rectify the defect.
In addition to the overall documentation, all legal or other
safety and accident prevention regulations as well as all
applicable standards and guidelines of the respective coun-
try of operation must be observed.
2.3.2

Obligations of the operator

2.3.2.1
Safety-conscious working
Only operate the aggregate in a technically flawless condi-
tion and in accordance with the provisions, safety precau-
tions and warnings included in these operating instructions.
Ensure and verify compliance with:
intended use
legal or other safety and accident prevention regula-
tions
safety regulations applying to handling hazardous sub-
stances
applicable standards and guidelines of the respective
country of operation
Provide for protective equipment.
2.3.2.2
Staff qualification
Ensure that staff involved in aggregate operation has read
and understood these operating instructions and all appli-
cable documents, particularly all safety, maintenance and
servicing information, prior to starting work.
Define clear roles and responsibilities and arrange for staff
monitoring.
All works must only be carried out by technically qualified
staff:
assembly, servicing, maintenance works
works on electrical equipment
Staff undergoing training must only work on the
pump/aggregate under the supervision of technically quali-
fied staff.