6.13 Adjustment options
DIP switch block CART
To set the options position the DIP switches
as shown in figures 10 till 13 (white). If not
all DIP switches are required for an option,
these are not shown (grey).
6.14 Adjust size of cartridge
Cartridge size Fig. 11
120 ml
ON
DIP
2
1
3
4
380 ml
ON
DIP
1
2
3
4
28
6.15 Carry out reset
Position Reset ON Fig. 12
Wait 10 SEC
ON
DIP
1
2
3
4
Position Reset OFF Fig. 13
ON
DIP
1
2
3
4
ATTENTION
The DIP switch has to remain in this
position up to 10 s. A successful reset is
indicated by a simultaneous lighting of the
red and the green LEDs. After the reset
make sure to adjust the correct cartridge
size again.
6.16 Venting/ functional control
Venting position Fig. 14
ON
DIP
1
2
3
4
Serves to vent and to check the function
after changing the cartridge.
ATTENTION
Use the venting position only for a short
time. Permanent operation in this position
will result in premature reaching of the no-
minal durability of the drive unit.
6. Assembly