INFORMATION ABOUT GAS FRYER MINIMA SERIES

This manual applies to our Gas Fryers Minima Series, Type A Category II (Natural Gas and L.P.G.).
See table 1.1 - 2.3.
The label according to EN437 and EN203 regulations, Part 1, is located at back and inside.
Example for Italy label:
Category II 2H3÷
Pe = Incoming Pressure
Pi = Nozzle Pressure
2.2

INSTALLATION

2.2.1

LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH

The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Hygienic regulations.
2.2.2

INSTALLATION PLACE

- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2 cu.m/hr x kW P.T.
(Thermal capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed
2.2.3

POSITIONING

- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
2.2.4
MOUNTING THE TOP UNITS ON A BASE OR AN EXTENDING SUPPORT
All Top units are supplied with height-adjustable feet (P):
- When the unit is to be placed free on a table or a surface,
tighten or loosen the feet (P) as shown in the illustration
till it is perfectly steady, then tighten the locknut (D)
so that the foot is blocked. To prevent slipping, insert
the rubber plugs (M) into the feet's lower holes.
- When the unit is to be fixed to a base or an extending
support, adjust the feet (P) till it is perfectly steady,
then tighten the locknut (D) so that the foot is blocked.
Subsequently fasten from beneath by way of M5 screws
(T) and respective washers, screwing them into the feet
as shown in the illustration.
GB
V
IT-GR-GB-ES-IE
PT
Cat.
II2H3+
II2H3+
P n
20,29/37
20,29/37
LU
IS-DK-FI-SE
Cat.
II2E3P
II2H3B/P
P n
20,37,50
20,29
G20
Qn
kW
(Hi)
G25
- 14 -
Mod.
Matr.N°
Hz
kW
FR-BE
NL
II2E+3+
II2L3P
20/25,29/37
25,30,50
AT-CH
DE
II2H3B/P
II2ELL3B/P
20,50
20,20,50
3
m
/h
G30
3
m
/h
G31
Type
tipo
mbar
NO
I3P
30
mbar
Kg/h
Kg/h

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gf46Gf66

Inhaltsverzeichnis