Herunterladen Inhalt Inhalt Diese Seite drucken

Disassemble The Mounting Bracket - Only For Incomplete Machines; Disassemble The Mechanical Seal - Speck-Pumpen IN-VB Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Maintenance
8.5.5
Disassemble the mounting bracket – only for incomplete machines
1.
Loosen the hexagon socket screws (914.2).
2.
Remove the coupling guard (681) from the drive lantern (161).
3.
Loosen the hexagon socket screws (914.1).
4.
Remove the coupling (849) with the pin (569). Lay the coupling on a clean and even surface.
5.
Remove the mounting bracket (89-11.03) from the drive lantern.
Fig. 14
8.5.6

Disassemble the mechanical seal

Fixed seal
(Fig. 15)
1.
Loosen the nuts (920.1).
2.
Remove the drive lantern (161).
3.
Remove the discharge cover (163) from the pump's outer casing.
4.
Remove the O-rings (412.1) from the stage casing.
5.
Remove the rotating unit of the mechanical seal (433) from the shaft.
6.
Remove the counter ring of the mechanical seal (433) from the discharge cover (163).
Fig. 15
30 EN
89-11.03
862
914.01
681
914.05
(920.1)
(163)
(914.1)
(523.1)
560
862
920.01
341
554.02
901.02
210
WG56.00.018-P
(849)
(161)
(433)
412.1
WG 56.00.015-P
11|2018

Werbung

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

In-vb-s

Inhaltsverzeichnis