Tab. 6:
Functions of the
DIP switch with
panic function E
Mounting
DIP switch with panic function E
Only with SBP locks with monitoring.
DIP Function
1
No function assigned
2
Terminating resistor
3
No function assigned
4
Power supply
–
active, 120 Ω
–
set correctly
not permitted
Factory setting
EN
–
Disabled
–
1
2
3
4
85