EN
82
Electrical connection
Installing and connecting the cable
The connecting cable must be guided in the door leaf from the lock side to the
hinge side. Then the cable must be routed from the door leaf into the door frame.
1
Observe the following when routing the connecting cable:
· We recommend routing the cable within the door leaf in a suitable conduit
having a minimum diameter of 7 mm.
· Do not kink the conduit and make any necessary bends as wide as possible.
· In order to avoid damaging the cable, it may only be guided around
rounded corners.
· A flexible lead cover must be mounted for the transition from door leaf to
frame, whereby the cover is firmly connected to the door leaf and frame.
2
Connect the cable as specified in the connection diagram and according to
the connection diagrams of the control system.
3
Ensure that the mains adapter matches the N7XXX SBP lock("Technical data",
page 96). Take into account the voltage loss through the connection cable
to ensure the lock functions.
Mounting